Pneumatic Actuator Noise Characteristics
1 Typical Noise Range
- Quarter turn pneumatic actuators generally produce noise levels between 60–85 decibels during operation.
- This range varies by size: smaller actuators often stay below 70 dB, while larger models may reach 85 dB due to increased air flow and mechanical movement.
2 Noise Sources
- Primary sources include air exhaust, gear meshing, and piston movement within the cylinder.
- Unlubricated components or misalignment amplify friction-related noise, while worn seals can cause whistling from air leaks.
3 Factors Influencing Noise
- Operating pressure affects noise—higher pressure increases air velocity, raising exhaust noise.
- Actuator design also matters: rack-and-pinion models tend to be quieter than scotch-yoke types, which may generate more vibration.
4 Noise Reduction Measures
- Install mufflers on exhaust ports to dampen air release sounds.
- Use sound-absorbing enclosures or insulation sleeves around the actuator.
- Regular lubrication of gears and bearings minimizes friction noise, while proper alignment reduces vibration.
5 Regulatory Compliance
- Industrial standards often limit workplace noise to 85 dB over 8 hours.
- High-noise environments may require additional safeguards like hearing protection or low-noise actuators designed for quiet operation.
If you want to learn more about low-priced products, please visit the following website: www.xm-valveactuator.com